print page print page

Hydronic M10 Coolant Heater

Hydronic M10 Coolant Heater

Heater type HYDRONIC M-II
      Heater HYDRONIC M10
      Version D 10 W
      Heating medium Water, Cooling fluid
      Control of the heat flow Power Large Medium Small
      Heat flow (watt) 9500 8000 3500 1500
      Fuel consumption (l/h) 1.2 0.9 0.4 0.18
      Electrical power (watt)(l/ in operation 86 60 39 35
      at start - after 25 Sek. 120
      in the control phase "OFF" 32
      Rated voltage 12 Volt 24 Volt
      Operating range
      . Lower voltage limit: An undervoltage protection in the controller
      switches the heater off on reaching the 10 Volt 20 Volt
      voltage limit.
      . Upper voltage limit: An overvoltage protection in the
      controller switches the heater off on reaching the 15 Volt 30 Volt
      voltage limit.
      Tolerable operating pressure up to 2 bar overpressure
      Flow rate of the water pump at 0.14 bar 1400 l/h
      Minimum water flow rate of the heater 500 l/h
      Fuel - see also "Fuel quality diesel heaters" page 27 Commercially
      available diesel (DIN EN 590)
      Tolerable operating temperature Operation Not running
      Heater / Control box -40 °C to +80 °C -40 °C to +85 °C
      Dosing pump -40 °C to +50 °C -40 °C to +85 °C
      Interference suppression class interference suppression class 5 to DIN EN
      55 025
      Weight with controller and water pump, without dosing pump approx. 6.2 kg